Array Capacity and Storage Efficiency

The capacity of a RAID array is determined by multiplying the capacity of the drives in the array by the number of non-redundant drives, i.e., drives used for data as opposited to parity or mirrored data. The more redundancy in the array, the lower the capacity of the array for a given number of drives. For example, six 40 GB hard disks in a RAID 0 array would yield a 240 GB array; in a RAID 5 configuration that same array would have 200 GB of usable capacity; in a RAID 1+0 setup, only 120 GB. The total capacity of the array depends on both the RAID level and the size and number of drives used.

The storage efficiency of the array is the percentage of the total size of the array that can be used for user data; it is more useful for comparing RAID levels because it does not depend on the size of the drives used in the array. It can be calculated simply by dividing the total usable capacity of the drive by the sum of the capacities of all the drives that underlie the array. For some RAID levels it is a constant, while for others it depends on the number of drives in the array. For example, the storage efficiency of RAID 0 is always 100%, and for RAID 1 and RAID 0+1, 50%. For levels that use striping with parity, storage efficiency increases as the number of drives is increased, because the number of parity drives is a constant and therefore diminishes as a percentage of the total.

While common parlance for calculating storage says to multiply the number of data-containing drives by the capacity of the drives, bear in mind that this assumes that all the drives are of the same size (which is the ideal way to set up a RAID array). In fact, the capacity of any RAID array is constrained by the size of the smallest drive in the array; it is that size that should be used when calculating capacity. So, the capacity of a RAID 5 array containing four drives that are 20 GB, 30 GB, 40 GB and 45 GB in size is 60 GB (calculated as 4-1 times 20 GB, the size of the smallest drive.) If you were to actually set up an array using such drives, 55 GB of space would be lost in what is sometimes called drive waste. If an array has drive waste due to unequal drive sizes, this will reduce the storage efficiency of the array as well, of course: the RAID 5 array given as an example here has a storage efficiency of (60 / 135) = 44%, instead of the 75% that would result if all the drives were the same size. Some controllers will let you use such "waste" as regular, non-RAID storage. See this discussion of drive size for related issues.

Next: Fault Tolerance and Availability


Home  -  Search  -  Topics  -  Up

The PC Guide (http://www.PCGuide.com)
Site Version: 2.2.0 - Version Date: April 17, 2001
Copyright 1997-2004 Charles M. Kozierok. All Rights Reserved.

Not responsible for any loss resulting from the use of this site.
Please read the Site Guide before using this material.
Custom Search